Indication 21 (38)
Installation Manual T-Rx 1000/1500 FSK12 FSK12 Version: B4 Document-ID: 945814-000 Author: SH
12 Indication
Status indication
Status indication
See “Figure 3. Receiver back side”
Bicolored LED
Mode Event Status LED
Status OK Not connected Fast GREEN 50/50 ms
CONNECTED, RCSS=ON Slow GREEN 30/970 ms
CONNECTED, RCSS=OFF Medium GREEN 50/250 ms
Poor radio reception Steady YELLOW
ERROR Receiver internal error Steady RED
Transmitter internal error Fast RED 50/50 ms
No supply power Off
13 Technical data
Technical data T-Rx 1000/1500
Housing Aluminium with ange fastening
Dimensions (H x W x D) 218x174x64 mm
Weight 1,6 kg
Protection IP67 (with mated connectors)
Working temperature -25 - +70 °C
Storage temperature -40 - +85 °C
Connector 62 pin AMP MCP 1,5/2,8
Interface T-Rx 1000: 25 on/off outputs. T-Rx 1500: Max 38 I/O. Partly congurable
Operating voltage 12/24 V DC nominal, range 10-32 V DC
Current consumption <350 mA (without external load at 12 V DC)
Relay Reaction times:
Reaction time on STOP function Maximum 550 ms
Safety Parameters for STOP function ISO13849-1:2006 category 3 PL d
Device monitoring
Under/over-voltage monitoring
Watchdog function
Checksum management of data and program code during runtime
Task counter management during runtime
Extensive diagnostics on RCSS outputs during runtime
Diagnostics on selected outputs
Process monitoring Dual channel architecture
Type designation RX IO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Åkerströms T-Rx 1000 and is the answer not in the manual?

Åkerströms T-Rx 1000 Specifications

General IconGeneral
BrandÅkerströms
ModelT-Rx 1000
CategoryRemote Control
LanguageEnglish

Related product manuals