If... Then...
the power levels are not within acceptable
limits,
continue with Step 3.
...................................................................................................................................................................................................
3
Thoroughly clean the fiber jumper connected to the LINE or SIG port of the amplifier
card raising the alarm.
...................................................................................................................................................................................................
4
Thoroughly clean the fiber bulkhead connector of the LINE or SIG port of the amplifier
card raising the alarm.
...................................................................................................................................................................................................
5
Perform a warm reset on the card where the OPR condition is raised.
CLI config card card_type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
6
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
7
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
8
Replace the card. Refer to “Replacing System Components” (p. 3-20). Follow the return
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
OPROOR
Trouble-clearing procedures
OPRPWRLOW
OPRPWRLOW (Out of Operational Range - Input Power Too
Low)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-236
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................