EasyManua.ls Logo

Alcatel-Lucent 1830 PSS-16 - Page 490

Alcatel-Lucent 1830 PSS-16
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
...................................................................................................................................................................................................
2
Retrieve the optical power levels at the receive port of the card where the alarm is raised.
CLI show interface
<shelf slot port>
WEBUI From the Equipment Tree, select the card, and select the desired port.
...................................................................................................................................................................................................
3
If... Then...
the power levels are within the acceptable
limits,
the problem may be with the card itself.
Proceed to Step 6.
the
power levels are not within acceptable
limits,
continue with Step 4.
...................................................................................................................................................................................................
4
Thoroughly clean the fiber jumper connected to the receive port of the OT or SVAC card
raising the alarm.
...................................................................................................................................................................................................
5
Thoroughly clean the fiber bulkhead connector of the receive port of the OT or SVAC
card raising the alarm.
...................................................................................................................................................................................................
6
Perform a warm reset on the card where the OPR condition is raised.
CLI config card card_type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
7
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
8
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
Trouble-clearing procedures
OPRTX
OPRTX (Channel Power Unstable)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-240
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Table of Contents

Related product manuals