Interface Configuration
7750 SR Interface Configuration Guide Page 33
Lane Tx Bias Current (mA)              78.0        75.0        25.0        20.0
Lane Rx Optical Pwr (avg dBm)          2.30        2.00      -11.02      -13.01
-------------------------------------------------------------------------------
Lane ID Temp(C)/Alm       Tx Bias(mA)/Alm   Tx Pwr(dBm)/Alm   Rx Pwr(dBm)/Alm
-------------------------------------------------------------------------------
    1              -              43.5                 -              0.42
    2              -              46.7                 -             -0.38
    3              -              37.3                 -              0.55
    4              -              42.0                 -             -0.52
===============================================================================
Transceiver Type   : CFP
Model Number       : 3HE04821ABAA01  ALU  IPUIBHJDAA
TX Laser Wavelength: 1294 nm                    Diag Capable     : yes
Number of Lanes    : 4
Connector Code     : LC                         Vendor OUI       : 00:90:65
Manufacture date   : 2011/02/11                 Media            : Ethernet
Serial Number      : C22CQYR
Part Number        : FTLC1181RDNL-A5
Optical Compliance : 100GBASE-LR4
Link Length support: 10km for SMF
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM)
===============================================================================
                              Value High Alarm  High Warn   Low Warn  Low Alarm
-------------------------------------------------------------------------------
Temperature (C)               +48.2     +70.0      +68.0       +2.0       +0.0
Supply Voltage (V)             3.24      3.46       3.43       3.17       3.13
===============================================================================
===============================================================================
Transceiver Lane Digital Diagnostic Monitoring (DDM)
===============================================================================
                                 High Alarm   High Warn    Low Warn   Low Alarm
-------------------------------------------------------------------------------
Lane Temperature (C)                  +55.0       +53.0       +27.0       +25.0
Lane Tx Bias Current (mA)             120.0       115.0        35.0        30.0
Lane Tx Output Power (dBm)             4.50        4.00       -3.80       -4.30
Lane Rx Optical Pwr (avg dBm)          4.50        4.00      -13.00      -16.00
-------------------------------------------------------------------------------
Lane ID Temp(C)/Alm       Tx Bias(mA)/Alm   Tx Pwr(dBm)/Alm   Rx Pwr(dBm)/Alm
-------------------------------------------------------------------------------
    1          +47.6              59.2              0.30            -10.67
    2          +43.1              64.2              0.27            -10.31
    3          +47.7              56.2              0.38            -10.58
    4          +51.1              60.1              0.46            -10.37
===============================================================================
The transceiver is programmed with warning and alarm thresholds for low and high conditions 
that can generate system events. These thresholds are programmed by the transceiver 
manufacturer. 
There are no CLI commands required for DDM operations, however, the show>port port-id 
detail command displays DDM information in the Transceiver Digital Diagnostics Monitoring 
output section.
DDM information is populated into the router’s MIBs, so the DDM data can be retrieved by 
Network Management using SNMP. Also, RMON threshold monitoring can be configured for the