Interface Configuration
7750 SR Interface Configuration Guide Page 503
Description This command is used to specify the IPv4 or IPv6 address of the BFD source.
The no form of the command removes this address from the configuration.
Default no local-ip-address
Parameters ip-address — Specifies the IP address.
Values ipv4-address: a.b.c.d
ipv6-address: x:x:x:x:x:x:x:x (eight 16-bit pieces)
x:x:x:x:x:x:d.d.d.d
x: [0 — FFFF]H
d: [0 — 255]D
max-admin-down-time
Syntax max-admin-down-time [down-interval | infinite]
no max-admin-down-time
Context config>lag>bfd>family
Description This command specifies the maximum amount of time the router will continue to forward traffic over a link
after the micro-BFD sessions has transitioned to a Down state because it received an ADMIN-DOWN state
from the far-end. This timer provide the administrator the configured amount of time to disable or de-provi-
sion the micro-BFD session on the local node before forwarding is halted over the associated link(s).
The no form of the command removes the time interval from the configuration.
Default no max-admin-down-time
Parameters down-interval — Specifies the amount of time, in seconds.
Values -1—3600
infinite — Specifies no end time to forward traffic.
max-setup-time
Syntax max-setup-time [up-interval | infinite]
no max-setup-time
Context config>lag>bfd>family
Description This command specifies the maximum amount of time the router will forward traffic over a link that has
transitioned from Standby to Active, before the micro-BFD session must be fully established (Up state).
The no form of the command returns the timer value to the default (0) which indicates that forwarding will
not start until the BFD session is established.
Default no max-setup-time