Interfaces
Page 504 7750 SR Interface Configuration Guide
Parameters up-interval — Specifies the amount of time, in milliseconds.
Values -1—60000
infinite — Specifies no end time to forward traffic.
multiplier
Syntax multiplier multiplier
no multiplier
Context config>lag>bfd>family
Description This command specifies the detect multiplier used for a micro-BFD session over the associated LAG links.
If a BFD control packet is not received for a period of multiplier X receive-interval then the session is
declared down.
The no form of the command removes multiplier from the configuration.
Default no multiplier
Parameters multiplier — Specifies the multiplier value.
Values 3—20
receive-interval
Syntax receive-interval receive-interval
no receive-interval
Context config>lag>bfd>family
Description This command specifies the receive timer used for micro-BFD session over the associated LAG links.
The no form of the command removes the receive timer from the configuration.
Default no receive-interval
Parameters receive-interval — Specifies the interval value, in milliseconds.
Values 10—100000
Default 100 ms for CPM3 or later, 1 sec for all other
remote-ip-address
Syntax remote-ip-address ip-address
no remote-ip-address
Context config>lag>bfd>family