Interfaces
Page 550 7750 SR Interface Configuration Guide
src-mac
Syntax src-mac ieee-address
no src-mac
Context config>redundancy>mc>peer>mcr>node>cv
Description This command specifies the source MAC address used for the Ring-Node Connectivity Verification of this
ring node.
A value of all zeroes (000000000000 H (0:0:0:0:0:0)) specifies that the MAC address of the system manage-
ment processor (CPM) is used.
Default no src-mac
Parameters ieee-address — Specifies the source MAC address.
vlan
Syntax vlan [vlan-encap]
no vlan
Context config>redundancy>mc>peer>mcr>node>cv
Description This command specifies the VLAN tag used for the Ring-node Connectivity Verification of this ring node. It
is only meaningful if the value of service ID is not zero. A zero value means that no VLAN tag is config-
ured.
Default no vlan
Parameters vlan-encap — Specifies the VLAN tag.
Values vlan-encap: dot1q qtag
qinq qtag1.qtag2
qtag 0 — 4094
qtag1 1 — 4094
qtag2 0 — 4094