4–15Component Test Procedures
Publication 1336 IMPACT-6.2 – March 1998
Important: Before you remove connections and wires from the
drive components, mark the connections and wires to
correspond with their component connections and
terminals to prevent incorrect wiring during assembly.
1. Remove power from the drive.
2. Check for zero volts at TB1 terminals +DC and –DC.
3. Check for absence of control voltage at:
TB10
TB11
L Option Board (if used)
4. Set your meter to measure resistance.
5. Test fuses F1, F2, and F3 for open conditions.
6. Replace the Precharge Board if any fuse shows an open
condition.

Table of Contents

Other manuals for Allen-Bradley 1336 PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1336 PLUS and is the answer not in the manual?

Allen-Bradley 1336 PLUS Specifications

General IconGeneral
Input Voltage200-240VAC, 380-480VAC, 500-600VAC
Output Frequency0-400 Hz
Frequency50/60 Hz
DimensionsVaries by model
WeightVaries by model
EnclosureNEMA 1
Output CurrentVaries by model
Power RatingVaries by model
CommunicationRS-485
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Storage Temperature-40 to 70°C (-40 to 158°F)
Humidity5 to 95% non-condensing
Control MethodSensorless Vector

Related product manuals