18 Rockwell Automation Publication KNX-RM009C-EN-P - May 2019
Kinetix 5500 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with the motor at 40 °C (104 °F) and the drive at 50 °C (122 °F) ambient, and rated line voltage. For
additional information on ambient and line conditions, refer to Motion Analyzer software.
Kinetix 5500 (200V-class operation) Drives/Kinetix VP Low Inertia Motor Curves
VPL-A1303F 4000 4000 18.60 7.75 (69.0)
45.90 15.36 (136)
2.50 (3.35)
2198-H040-ERSx
62.0 20.72 (183) 2198-H070-ERSx
VPL-A1304A 1600 1600 9.43 10.29 (91.0)
28.30 25.03 (221)
1.55 (2.08)
2198-H025-ERSx
33.76 28.45 (252) 2198-H040-ERSx
VPL-A1304D 3000 3000 18.40 10.20 (90.0)
45.90 21.48 (190)
2.60 (3.50)
2198-H040-ERSx
58.0 27.10 (240) 2198-H070-ERSx
VPL-A1306C 2000 2000 14.78 13.38 (118)
45.90 28.50 (252)
2.13 (2.86)
2198-H040-ERSx
55.83 34.62 (306) 2198-H070-ERSx
Bulletin VPL Motor Performance Specifications with Kinetix 5500 (200V-class operation) Drives (cont.)
Rotary Motor
Cat. No.
Rated Speed
rpm
Speed, max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW (Hp)
Kinetix 5500 Drives
(240V AC Input)
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H008-ERSx and VPL-A0631M
2.0
1.5
1.0
0.5
0
0
4000
8000
60002000
17.7
13.3
8.85
4.42
0
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H008-ERS
x and VPL-A0631E
17.7
13.3
8.85
4.42
0
2.0
1.5
1.0
0.5
0
0
3000
5000
40001000
2000
Torque
(N•m)
Torque
(lb•in)
0
0
1.0
2.0
3.0
5.0
4.0
8.85
17.7
26.5
35.4
44.2
2198-H008-ERS
x and VPL-A0633C
Speed (rpm)
0
2000
30001000
Torque
(N•m)
Torque
(lb•in)
2198-H008-ERS
x and VPL-A0632F
3.0
2.5
2.0
1.5
1.0
0.5
0
Speed (rpm)
0
3000
5000
4000
1000
2000
26.5
22.1
17.7
13.3
8.85
4.42
0
= Intermittent operating region
= Continuous operating region
= Drive operation with 200V AC rms input voltage