Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 291
Troubleshoot the Kinetix 5700 Drive System Chapter 7
Table 144 - Drive Behavior, FLT Sxx Fault Codes
Exception Fault Code Exception Text
Inverter
Modules
2198-xxxx
Permanent
Magnet
Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignore
Alarm
Minor Fault
Major Fault
FLT S02 – MTR COMMUTATION Motor Commutation Fault -ERSx X – –––XDisable/Coast
FLT S03 – MTR OVERSPEED FL Motor Overspeed Factory Limit Fault -ERSx X X –––XDisable/Coast
FLT S04 – MTR OVERSPEED UL Motor Overspeed User Limit Fault
-ERS3 (series A)
X X XXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Hold
FLT S05 – MTR OVERTEMP FL
Motor Overtemperature Factory Limit Fault -ERS3 (series A)
X
– ––––Disable/Coast
Motor Overtemperature Factory Limit Fault
(If #589 vertical load control)
-ERS4 X
––––Current Decel/Disable
Motor Overtemperature Factory Limit Fault
(If not #589 vertical load control)
––––Disable/Coast
FLT S07 – MTR OVERLOAD FL Motor Thermal Overload Factory Limit Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
––– Ramped Decel
(5)
/Disable
FLT S08 – MTR OVERLOAD UL Motor Thermal OverLoad User Limit Fault
-ERS3 (series A)
X X XXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Hold
FLT S09 – MTR PHASE LOSS Motor Phase Loss -ERSx X – XXXXDisable/Coast
FLT S10 – INV OVERCURRENT Inverter Overcurrent Fault -ERSx X X –––XDisable/Coast
FLT S11 – INV OVERTEMP FL
Inverter Overtemperature Factory Limit Fault -ERS3 (series A)
XX
–––
X
Disable/Coast
Inverter Overtemperature Factory Limit Fault
(If #589 vertical load control)
-ERS4
– – – Current Decel/Disable
Inverter Overtemperature Factory Limit Fault
(If not #589 vertical load control)
––– Disable/Coast
FLT S13 – INV OVERLOAD FL
Inverter Thermal Overload Factory Limit
Fault
-ERS3 (series A)
XX
–––
X
Disable/Coast
-ERS4 – – – Current Decel/Disable
FLT S14 – INV OVERLOAD UL Inverter Thermal Overload User Limit Fault
-ERS3 (series A)
X X XXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Hold
FLT S16 – GROUND CURRENT Ground Current Factory Limit Fault
-ERSx
Single-axis
inverters
X X –––XDisable/Coast
FLT S22 – AC POWER LOSS Converter AC Power Loss Fault
-ERS3 (series A)
X X XXXX
Decel/Disable
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Disable
FLT S27 – BUS REG OVERTEMP FL
(1)
Bus Regulator Overtemperature Factory
Limit Fault
-ERSx X X –––XDisable/Coast
FLT S32 – BUS CAPACITOR MODULE
FAI LURE
Bus Capacitor Module Failure
-ERS3 (series A)
X X XXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Hold
FLT S33 – BUS UNDERVOLT FL Bus Undervoltage Factory Limit Fault
-ERS3 (series A) X X – – – X Decel/Disable
-ERS4
-ERS3 (series B)
X X – – – X Ramped Decel
(5)
/Disable
FLT S34 – BUS UNDERVOLT UL Bus Undervoltage User Limit Fault
-ERS3 (series A)
X X XXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(5)
/Hold
FLT S35 – BUS OVERVOLT FL Bus Overvoltage Factory Limit Fault -ERSx X X –––XDisable/Coast