Publication 2711P-UM001B-EN-P
8-12 Troubleshooting and Maintenance
System Identification Errors
The error messages in this section appear on startup if incorrect or
invalid components are used with the PanelView Plus 700-1500
terminals.
• The following dialog appears if a VersaView CE Logic Module is
attached to a PanelView Display Module or a PanelView Plus
Logic Module is attached to a VersaView CE Display Module. It
is recommended that you use a VersaView CE Display Module
with a VersaView CE Logic Module and a PanelView Plus
Display Module with a PanelView Plus Logic Module. This is a
warning allowing you to continue to operate.
• The following dialog appears if the PanelView Plus Logic
Module contains a 6189-RWx Internal Compact Flash card for
the VersaView CE terminal.
After pressing OK, you will be asked to power off the terminal
and insert a valid 2711P-RWx Internal Compact Flash card for
the PanelView Plus terminal.
• The following dialog appears if the VersaView CE Logic Module
contains a 2711P-RWx Internal Compact Flash card for the
PanelView Plus terminal
.
After pressing OK, you will be asked to power of the terminal
and insert a valid 6189-RWx Internal Compact Flash card for the
VersaView CE terminal.
700-1500 only
(6189-RWX)