15
Setting Up a 15A Model:
BydefaultthesespapoolswillNOTdrawmorethan15Aatanyonetime.Thisis
thedefaultfactorysetupwhichdisablestheheaterwhenthepumps(jets)are
turnedon*.
A15ampcablewith3-pinplughasbeenpre-wiredtothespapool’ssystem
controllerandcanbefoundcoiledupinsidethecabinet.Tondoutwhichcabinet
toremove,seeyourspapool’scorrespondingtechinfo/wiringpage(usingthe
tableonthepreviouspage).
Setting Up a 25A/32A/45A Model:
A15Aspapoolrequiresa15Asocketandresidualcurrentdevice
(RCD)forthedefaultsetup.
A25A/32A/45Aspapoolrequiresadedicatedfeedfromyourcircuit
boardandappropriateResidualCurrentDevice&Isolationswitch.
Anelectricianisrequiredtosetupandconnecttheappropriatewiring.Tolocate
thesystemcontroller,seeyourspapool’scorrespondingtechinfo/wiringpage
(usingthetableonthepreviouspage).
Thecableshouldbefedthroughthecabinetwall(acablegrommetissupplied
intheiPackshouldyouwishtousethis)andadrillwitha60mmhole-saw
attachmentwillprovidetherightsizeforthegrommet(seeaboveimage).
Alternatively,atightertcanbeachievedwithoutthegrommetbyjustusingadrill
bitthesamesizeastheexdiameteranddrillingthroughthecabinetwall.
Ifa45Aconnectioncannotbeachieved,loadshedding/limitingcanbeappliedto
restrictthetotalampdrawnbythespapool,allowingyoutofeed25-32A.
Informationforloadshed&changing15Ato25Acanbedownloaded
fromoursupportpageat:http://alpinespas.co.nz/support/
*NOTE: Customers generally prefer the default 15A factory setting, however it is possible
to wire a dedicated 25A electrical feed for both the heater and pump to run simultaneously.
A guide for your electrician can be downloaded from our support page.
Thecablecanbeexitedthroughthecabinetwall(acable
grommetissuppliedintheiPack).Adrillwitha60mm
hole-sawattachmentwillprovidetherightsizeforthe
grommet.
Cable grommet after installation