EasyManua.ls Logo

Alpine Spas SPA POOL - Diagnostic Messages - SpaNet Control Panel

Default Icon
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
94
9. SERVICE INFORMATION
Diagnostic Messages - SPANET TOPSIDE CONTROL PANEL
MESSAGE CAUSE ACTION REQUIRED
ER-2 HEATER PLUG
(noheatsensorcommunication)
Internalheatersensorcommunication
error
TurnmainspowerOFF,wait5minutes
then restart spa pool. Contact tech if
problemnotresolved
ER-3 WATER PRIME
(primehasfailed)
Airdetectedinheatertube
Low water level
Dirtyltercartridges
Airlockinpipework
Slice-valvesshut
PressPumpAbuttontoretrywaterprime.
Checkspapoolwaterlevel(rellif
necessary)
Removeandcleanltercartridgesthen
pressPumpAbuttontoretryprime
Bleedairfrompipesbylooseningbarrel
unionsonpumps
Checkallslicevalvesareopen
ER-4 THERMAL TRIP
(Heaterthermaltripactivated.Heaterhas
beenactive&hashadinsufcientwater
owovertheelement.Lowornowater
owhascausedtheheatertemperature
toexceeditsmaximumlimits&thespa
poolcontrolhasshutdownoperationto
preventanydamagetotheheaterunit)
Low water level
Airlockinpipework
Dirtyltercartridges
Slice-valvesshut
Checkspapoolwaterlevel(rellif
necessary)
Bleedairfrompipesbylooseningbarrel
unionsonpumps
Removeandcleanltercartridgesthen
pressPumpAbuttontoretryprime
Checkallslicevalvesareopen
ER-5 POOL TOO HOT
(Watertemperaturetoohigh,sensor
reading+45degrees)
Highambienttemp(summer)
Excessiveltrationtime
Turnoffspapool,removecoverandallow
watertocoolbeforeswitchingbackon.
Reduceltrationtime
ER-6 12V OVERLOAD 12Vportcurrentdrawexceeding1Alimit Call for service
ER-8 CTRL FAULT HVS
(heaterrelayonwhenitshouldbeoff)
PowerSurge
Periodsoflow/highvoltage
Water on controller terminal
TurnmainspowerOFF&backONagain
Inspectinsidespapoolcabinetforleaksor
evidenceofwaterexposuretocontroller.
Turnoffspapool,drywater/xleakandlet
controllerdryout
ER-10 OVER CURRENT
(Mains230vcurrentdrawabovecurrent
limitedC.LMTdetected)
Componentscurrentdrawtoolargefor
C.LMT setting
PowerOFF/ON.CheckC.LMT/L.SHD/
L.LMT settings are correct. Do elimination
testoncomponentsusingthecontrol
paneltoidentifywhichconnectionis
causingthefault

Table of Contents

Related product manuals