Faults
Amaco BAG0028.0 04.06
27
8.4 Checking sensor ”ha” for function
After the computer has been checked as described in para. 8.2 and
8.3 and no error could be found, a possible error can then only be
caused by a wrongly fitted sensor or a defective senso r or sensor
cable. Check the sensor:
1. Unbolt sensor
ha
and magnet from the seed drill.
2. Connect sensor cable
ha
to the calculator.
3. Enter code
F.1
and briefly press key
ha
.
4. Pass the magnet immediately in front of the sensor (simulation
of impulses).
The calculator processes the simulated impulses and shows th is
by adding them in the display.
If the calculator does not process the impulses correctly the
sensor must be exchanged.
If the calculator operates properly:
Reduce the gap between sensor and magnet o n the seed drill.

Table of Contents