Settings
40
AMADRILL+ BAH0040-9 01.19
15. Press buttons
and simultaneously
Start the metering roller drive (electric motor) for the calibration test.
The number of engine revolutions for the calibration test until the
signal tone sounds is governed by the seeding rate:
0 to 14.9 kg motor revolutions on 1/10 ha
15 to 29.9 kg motor revolutions on 1/20 ha
30 kg or more Engine revolutions to 1/40 ha.
16. When the signal sounds press the
button.
In its calculations, the AmaDrill+ takes account of the additional rotations after the acoustic
signal.
The theoretical calibrated seed quantity [kg] is indicated in the display.
17. Weigh the seed quantity actually collected [kg].
18. Press the
or button.
Enter the weight [kg] of the collected seed quantity.
19. Press
.
Save the value.
20. If the collected seed quantity deviates significantly from the displayed theoretical seed quantity,
the calibration test is to be repeated.