Tables
62
AMADRILL+ BAH0040-9 01.19
9.3 Table for calibration values / crank turns (guide values)
The following table values are reference values.
If the actual calibration value (pul./100 m) deviates from the table
value, for the calibration test the following will also change
The number of crank turns
The rotational speed of the electric drive motor.
The number of crank turns for the calibration test can be recalculated
(see front). The rotational speed of the electric drive motor during the
calibration test is automatically based on the actual calibration value
(pul./100 m).
Mechanical seeding technology
Mounted seed drills
D9 Super / Special
Working width 2.5 m 3.0 m 3.5 m 4.0 m 6.0 m
Tyres
Calibration value
(imp./100 m)
Crank turns on 1/40 ha
6.00 – 16
180/90 – 16
740
46.0 38.5 33.0
10.0/75 – 15
711
28.0 18.5
Mounted seed drills
(mechanical)
Working width
2.5 m 3.0 m 3.5 m 4.0 m
Calibration value
(imp./100 m) Crank turns on 1/40 ha
AD 25/3000 Special
AD 30/35/4000 Super
617 27.0 22.5 19.0 17.0