6.7.5 Calibration test for seed drills with Vario gear motor (up to model year 2014)
Equipment:
AmaDrill+
up to year of manufacture 2014
Seed drill
with electric cylinder (Fig. 30/1).
Fig. 30
1. Prepare the seed drill for the calibration test as described in the seed drill operating manual (set
up calibration trough, etc.).
2. Press
.
3. Press the
or button.
Enter the desired application rate (kg/ha).
4. Press
.
5. Press
.
6. Press the
or button.
Enter the scale value of the pointer (e.g. 50, refer to the seed drill operating manual) for the first
calibration test (Fig. 30/2).
7. Press
.
8. Press the
and buttons simultaneously.
The pointer (Fig. 30/2) moves to the scale value entered (e.g. 50).
The scale value must be the same as the gear setting value displayed
on the AmaDrill+.
Otherwise, calibrate the Vario gearbox
(see section "Calibration of the Vario gearbox", Seite 29).