Tables
AMALOG BAH0017.6 08.19
37
9 Tables
9.1 Machine data table
Mode 1 Code Activating functions of the control terminal
1
Activate all functions of the control terminal
2
Only activate the hectare counter of the control terminal
Mode 2 Code Number of track marker sensors
0
Machine with 2 track marker sensors,
e.g. front tank seeding combination with 2 track
marker sensors (Fig. 34/1).
Fig. 34
1
Machine
with 1 track marker sensor
on hydraulic valve (Fig. 35/1)
Fig. 35
Machine
with 1 track marker sensor
on marker changeovers (Fig. 36/1)
Fig. 36
2 to 99
For machine
with track marker but without track marker sensor
without track marker and without track marker sensor
the numbers 2 to 99 correspond to the time (seconds) between stopping
(gearbox standstill) and continued counting of the tramline counter.
For seed drills without track marker sensor, the tramline counter shifts on as
soon as the set time expires after gearbox standstill, e.g. after the seed drill is
raised for turning at the end of the field.
In event of a brief pause within the set time, the tramline counter does not con-
tinue to count.