EasyManua.ls Logo

Ametek Sorensen SG Series - 6.14.4 Hardware Trigger Example; 6.14.5 Ramp V Example; 6.14.6 Ramp I Example

Ametek Sorensen SG Series
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCPI Command Operation SG Series Programming
6-44 M550129-03 Rev L
6.14.4 Hardware Trigger Example
This example applies only to units with the External User Interface
(Currently only available on Ethernet versions).
Program a unit to execute a test sequence “TEST02” when a hardware
trigger is issued using the External User Interface (the sequence must be
programmed before it can be loaded).
HTRIG:SEQ “TEST02” // load the sequence named “TEST02” into memory.
HTRIG:SEQ? // verify that “TEST02” was loaded.
HTRIG:ARM 1 // arm the hardware trigger.
HTRIG:ARM? // verify that the hardware trigger was armed.
// invoke the hardware trigger.
// sequence “TEST02” will run.
PROG:STAT? // verify that the sequence is running or finished.
6.14.5 Ramp V Example
Program a unit with no load at the output to ramp its output voltage from
5 VDC to 25 VDC in 30 seconds.
Note: The maximum output voltage is dependent upon the power supply rating.
// Use SYST:ERR? after each command to verify no programming errors.
// turn on the unit.
*CLS // clear the unit to its power-on default settings.
*RST // reset the unit.
SOUR:CURR 33.0 // program output current to 33.0 A.
SOUR:VOLT 5.0 // program output voltage to 5.0 VDC.
SOUR:VOLT:RAMP 25.0 30.0 // program voltage to ramp from the present
// value (5.0 VDC) to 25.0 VDC in 30 seconds.
6.14.6 Ramp I Example
Program a unit with the output shorted to ramp its output current from 5A
to 25A in 30 seconds.
// Use SYST:ERR? after each command to verify no programming errors.
// turn on with no load at the output.
*CLS // clear the unit to its power-on default settings.
*RST // reset the unit.
// short the output.
SOUR:VOLT 33.0 // program output voltage to 33.0 VDC.
SOUR:CURR 5.0 // program output current to 5.0 A.
SOUR:CURR:RAMP 25.0 30.0 // program current to ramp from the present

Table of Contents