M550221-01 Rev U www.programmablepower.com
SGI Series DC
Power Supplies
Operation Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen SGI Series and is the answer not in the manual?

Ametek Sorensen SGI Series Specifications

General IconGeneral
Frequency47-63 Hz
Control InterfaceAnalog, RS-232, Ethernet
CoolingForced air
Operating Temperature0°C to 50°C
ProtectionsOvervoltage, Overcurrent, Overtemperature
DimensionsVary depending on model. Rack mountable (1U to 6U)
Output Voltage Range0-5V to 0-600V (depending on model)

Summary

Section 1 Overview

1.2 Specifications

Details environmental, electrical, and physical characteristics of the SGI Series power supplies.

1.2.2 Electrical Characteristics

Covers input power voltage, frequency, configuration, power factor, efficiency, and hold-up time.

Section 2 Installation

2.4 Input/Output Connections

Details AC input and DC output connection requirements and safety precautions.

2.6 LOAD CONSIDERATIONS

Gives guidelines for incorporating protective diode networks for inductive or stored-energy loads.

Section 3 Operation

3.2 Basic Operation and Output Verification

Provides an overview of front panel programming and initial functional tests.

3.2.1 Initial Setup

Details the initial setup steps before connecting the unit to AC mains power.

3.2.2 Default Programming Menu

Explains operation in Constant-Voltage, Constant-Current, and OVP modes using the default menu.

3.2.3 Constant-Voltage Mode Operation

Guides on verifying operation in Constant-Voltage mode with step-by-step instructions.

3.2.4 Constant-Current Mode Operation

Guides on verifying operation in Constant-Current mode with step-by-step instructions.

3.2.5 Overvoltage Protection

Explains how to verify the Overvoltage Protection (OVP) function.

3.6 Editing

Details how to edit values and make changes to settings on the power supply.

3.8 Programming/Operating Functions

Covers various programming and operating instructions for the power supply.

3.8.1 Voltage, Current, and Overvoltage Protection Programming

Explains how to program voltage, current, and OVP settings via the front panel.

3.8.2 Save

Details how to save programmed configurations (voltage, current, OVP, output condition).

3.8.3 Recall

Explains how to recall previously saved output configurations.

3.8.4 Sequencing

Introduces the sequencing function for automating test sequences.

3.8.5 Constant-Power Mode

Describes the Constant-Power mode for regulating output at a set power level.

3.8.11 Remote

Covers remote operation via Ethernet or GPIB, including LXI settings.

3.9 Remote Analog Control Connector (J1)

Details the Analog Control Connector (J1) for remote programming and monitoring.

3.10 Remote Current Programming

Explains remote programming of output current using resistance or voltage sources.

3.11 Remote Voltage Programming

Explains remote programming of output voltage using resistance or voltage sources.

3.13 Remote Output On/Off Control

Covers remote control of output ON/OFF via contact closure or external sources.

3.16 Parallel and Series Operation

Covers connecting multiple supplies in parallel for higher current or series for higher voltage.

Section 4 Calibration and Verification

4.2 Calibration and Verification Procedures

Details calibration procedures for various modes and options.

4.2.1 Constant-Current Mode

Provides steps for calibrating the Constant-Current mode using external sources.

4.2.2 Constant-Voltage Mode

Provides steps for calibrating the Constant-Voltage mode using external sources.