Do you have a question about the Ametek Sorensen SGI Series and is the answer not in the manual?
Frequency | 47-63 Hz |
---|---|
Control Interface | Analog, RS-232, Ethernet |
Cooling | Forced air |
Operating Temperature | 0°C to 50°C |
Protections | Overvoltage, Overcurrent, Overtemperature |
Dimensions | Vary depending on model. Rack mountable (1U to 6U) |
Output Voltage Range | 0-5V to 0-600V (depending on model) |
Details environmental, electrical, and physical characteristics of the SGI Series power supplies.
Covers input power voltage, frequency, configuration, power factor, efficiency, and hold-up time.
Details AC input and DC output connection requirements and safety precautions.
Gives guidelines for incorporating protective diode networks for inductive or stored-energy loads.
Provides an overview of front panel programming and initial functional tests.
Details the initial setup steps before connecting the unit to AC mains power.
Explains operation in Constant-Voltage, Constant-Current, and OVP modes using the default menu.
Guides on verifying operation in Constant-Voltage mode with step-by-step instructions.
Guides on verifying operation in Constant-Current mode with step-by-step instructions.
Explains how to verify the Overvoltage Protection (OVP) function.
Details how to edit values and make changes to settings on the power supply.
Covers various programming and operating instructions for the power supply.
Explains how to program voltage, current, and OVP settings via the front panel.
Details how to save programmed configurations (voltage, current, OVP, output condition).
Explains how to recall previously saved output configurations.
Introduces the sequencing function for automating test sequences.
Describes the Constant-Power mode for regulating output at a set power level.
Covers remote operation via Ethernet or GPIB, including LXI settings.
Details the Analog Control Connector (J1) for remote programming and monitoring.
Explains remote programming of output current using resistance or voltage sources.
Explains remote programming of output voltage using resistance or voltage sources.
Covers remote control of output ON/OFF via contact closure or external sources.
Covers connecting multiple supplies in parallel for higher current or series for higher voltage.
Details calibration procedures for various modes and options.
Provides steps for calibrating the Constant-Current mode using external sources.
Provides steps for calibrating the Constant-Voltage mode using external sources.