SG Series Programming SCPI Command Operation
M550129-03 Rev L 6-49
PROG:DEF 2, RAMPTOV, 3, 5, 4, 11, 10 //ramp from 3 volts to 5 volts in
10 sec
PROG:DEF 3, VIMODE, 5, 4, 11, 10 //hold 5 volts for 10 sec
PROG:DEF 4, RAMPTOV, 5, 3, 4, 11, 10 //ramp from 5 volts to 3 volts in
10 sec
PROG:DEF 5, VIMODE, 3, 4, 11, 10 //hold 3 volts for 10 sec
PROG:DEF 6, SUBCALL, SEQ2 //call SEQ2 as a subsequence
PROG:DEF 7, VIMODE, 4, 5, 11, 6 //go to 4 volts, 5 amps, 11 volts ovp, for 6
sec
PROG:DEF 8, STOP //stop running the sequence while
the unit remains at the state of the
last command within the
sequence.
PROG:STAT COMPLETE
PROG:SAVE:SEL
PROG:STAT?
Response: Ram[0]=“STOPPED”,Slave[0]=”STOPPED”
OUTP:STAT ON
PROG:STAT RUN
The output of the supply for Example 3 should look like the following diagram:
Figure 6-3. Power Supply Output for Example 3
The above diagram shows how the new SEQ1 sequence looks when SEQ2 is installed as a
subsequence.
3 volts for 10 sec
3 volts for 10 sec
5 volts for 10 sec
Ramp up to 5
volts in 10 sec
Ramp down to 3
volts in 10 sec
10 volts for 5 sec
Ramp down to 2
volts in 9 sec
4 volts for 6 sec

Table of Contents