SG Series Programming SCPI Command Operation
M550129-03 Rev L 6-19
Sets the foldback (program down) mode of the supply. Valid
arguments are 0 (OFF or do nothing, do not program down to zero),
1 (program down to zero upon entering constant-voltage mode), or
2 (program down to zero upon entering constant-current mode).
Returns the set foldback (program down) mode of the supply.
0 = OFF; will not program down.
1 = will program down to zero upon entering constant-voltage
mode.
2 = will program down to zero upon entering constant current mode
Sets the sense relay signal open or close. Valid arguments are
1/ON or 0/OFF.
Returns the setting of the sense relay signal:
1 = ON 0 = OFF
Sets the output to zero or the programmed value; opens or closes
the isolation relay. Valid arguments are 1/ON or 0/OFF. *RST
state value is ON.
Returns the state of the output:
1 = ON 0 = OFF
Returns the integer value 1 (TRIPPED) or 0 (UNTRIPPED) state of
the output.
6.8 STATUS SCPI COMMAND SUBSYSTEM
This section first presents a tree summary of the STATus commands and
then provides a tabular description.
Note: See Section 5 for further information.
6.8.1 STATUS SCPI Command Summary
STATus
:OPERation
:CONDition?
:ENABle <NR1>
:ENABle?
:EVENt?
:PRESet
:PROTection
:CONDition?
:ENABle <NR1>
:ENABle?
:EVENt?
:SELEct <NR1>
:SELEct?
:QUEStionable
:CONDition?
:ENABle <NR1>
:ENABle?
:EVENt?