EasyManua.ls Logo

Ametek Sorensen SG Series - 6.11 Trigger SCPI Command Subsystem; 6.11.1 Trigger SCPI Command Summary; 6.11.2 Trigger SCPI Command Reference

Ametek Sorensen SG Series
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCPI Command Operation SG Series Programming
6-26 M550129-03 Rev L
6.11 TRIGGER SCPI COMMAND SUBSYSTEM
This section describes the programming soft trigger function.
6.11.1 TRIGGER SCPI Command Summary
TRIGger
:ABORt
:RAMP
:TYPE <1|2|3>
6.11.2 TRIGGER SCPI Command Reference
The letter “C” in the “SCPI” column means that the command syntax is
SCPI compliant; an “N” in the “SCPI” column means that the command
syntax is not part of the SCPI definition.
Command
Description
SCPI
TRIGger
Trigger subsystem.
C
:ABORt
Stops the execution of a currently running trigger function, and
clears all settings of voltage and current.
N
:RAMP
Executes voltage or current ramping function previously
programmed by the SOURce command, i.e.,
SOURce:VOLTage:RAMP
SOURce:CURRent:RAMP
N
:TYPe<1|2|3>
Executes voltage and current values previously programmed by
the SOURce command i.e.,
SOURce:VOLTage:LEVel:TRIGger
SOURce:CURRent:LEVel:TRIGger
Valid arguments are 1 (Voltage), 2 (Current), or 3 (Both).
N

Table of Contents

Related product manuals