EasyManua.ls Logo

Ametek Sorensen SG Series - Figure 5-8. Example of Open-Collector, TTL Input, and Relay Output Circuits

Ametek Sorensen SG Series
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ethernet Configuration and Remote Programming SG Series Programming
5-12 M550129-03 Rev L
SCPI Command
Internal Relay Contact State
Pin (return to Pin-5)
OUTP:ISOL 0
ISOLATION relay = open
7
OUTP:ISOL 1
ISOLATION relay = closed
OUTP:SENSE 0
REMOTE SENSE relay = open
8
OUTP:SENSE 1
REMOTE SENSE relay = closed
OUTP:POL 0
POLARITY relay = open
6
OUTP:POL 1
POLARITY relay = closed
Figure 5-8. Example of Open-Collector, TTL Input, and Relay Output Circuits
CAUTION
External relays must not be hot-switched; ensure that the voltage across the relay
contacts and the current through them is zero prior to changing the relay states.