SG Series Programming SCPI Command Operation
M550129-03 Rev L 6-15
Sets the output voltage of the supply in volts (default) or in
millivolts.
Returns the output voltage of the supply in volts or in
millivolts.
Sets the output voltage of the supply in amps (default) or in
milliamps.
Returns the output voltage of the supply in amps or in
milliamps.
Sets the upper soft limit on the programmed output voltage.
The soft limit prevents the supply from being inadvertently
programmed above the soft limit, thus providing a method
for protecting the load against damaging voltages.
Returns the upper soft limit set on the programmed output
voltage.
Sets the upper soft limit on the programmed output voltage.
Returns the upper soft limit on the programmed output
voltage.
Sets the overvoltage protection trip point in volts (default) or
in millivolts.
Returns the set overvoltage protection trip point in volts
(default) or in millivolts.
Sets the overvoltage protection trip point in volts (default) or
in millivolts.
Returns the set overvoltage protection trip point in volts or in
millivolts.
Returns 1 (TRIPPED) or 0 (UNTRIPPED) state of the
overvoltage protection circuit.
Returns the state 1 (ON) or 0 (OFF) If the overvoltage
protection is enabled.
Clears the overvoltage protection circuit.
Sets the output voltage to ramp from the present value to the
specified value (first argument) in the specified time (second
argument). See Ramp Function description Section 6.5.3.
Returns 1 if the ramp is in progress, and 0 if the ramp is
completed.
Aborts ramping and clears trigger mode.
Returns the ramping status of all channels.
Sets the value of the output voltage ramp to be implemented
when the hardware trigger is received.
Returns the value of the output voltage ramp to be
implemented when the hardware trigger is received.