SCPI Command Operation SG Series Programming
6-30 M550129-03 Rev L
Command
Description
SCPI
:GAIN?
Returns the value of the gain for current
measurements.
N
:OFFSet <NRf>
Sets the value of the offset for current
measurements.
N
:OFFSet?
Returns the value of the offset for current
measurements.
N
:POINt <1|2> <NRf>
Sets the current measurement calibration point
(1 or 2). The actual output current is measured with
an external meter.
N
:VOLTage
Calibrate Measure Voltage subsystem
N
:ADC?
Returns the integer value of the A/D for the voltage
measurement.
N
:CALCulate
Calculates the value of the gain and offset for voltage
measurements.
N
:GAIN <NRf>
Sets the value of the gain for voltage measurements.
N
:GAIN?
Returns the value of the gain for voltage
measurements.
N
:OFFSet <NRf>
Sets the value of the offset for voltage
measurements.
N
:OFFSet?
Returns the value of the offset for the voltage
measurements.
N
:POINt <1|2> <NRf>
Sets the voltage measurement calibration point
(1 or 2). The actual output voltage is measured with
an external meter.
N
:MODel
Calibrate Model subsystem
N
:LASTCALDATE<NRf>
(Ethernet only) Sets the date last calibrated;
format: MM DD YYYY (space after MM and DD
required)
N
:LASTCALDATE?
(Ethernet only) Returns the date last calibrated.
N
:NEXTCALDATE<NRf>
(Ethernet only) Sets the date next calibration is
required;
format: MM DD YYYY (space after MM and DD
required)
N
:NEXTCALDATE?
(Ethernet only) Returns the date next calibration is
required.
N
:POWERON <string>
Sets the default output enable condition at power on.
Input format:
“ON,INIT” enables the output at next power on
“OFF,INIT” disables the output at next power on
NOTE: Quotation marks are required in the
command string.
N
:POWERON?
Returns the status of the output enable condition at
power on
N
:RESET <string>
Sets the default output enable condition when the
*RST command is issued.
Input format:
“ON,INIT” enables the default output
“OFF,INIT” disables the default output
NOTE: Quotation marks are required in the
command string.
N
:RESET?
Returns the status of the default output enable
condition when the *RST command is issued
N