9 | ANYLOAD OCS Series Electronic Crane Scale User’s Guide
Function
o The scale shall clear the tare weight and shall return to gross
mode. It will display all subsequent readings in G
ROSS
M
ODE
.
o
The TARE indicator will light off.
o
The weight reading is added with the tare weight.
Condition
o
The scale must not be in H
OLD
mode otherwise an error message
will display
.
o
The scale must be in N
ET
M
ODE
otherwise the action will treat as T
ARE
I
N.
HOLD
Action
o To H
OLD
the weight reading, press HOLD key on scale or on
remote controller. Some models are not equipped with this
feature.
o
To unlock current reading, press HOLD key on scale or on
remote controller again.
Function
o The HOLD indicator will light on.
o The display will freeze at the held weight value even removing or
adding weights on the scale.
o
Pressing the HOLD key at HOLD mode, the indicator will
light off and the scale is unlocked. The scale will show the current
weight reading.
Condition
o To H
OLD
the scale, it must be stabled otherwise an error message
will display