5 | ANYLOAD OCS Series Electronic Crane Scale User’s Guide
3. Specifications
Accuracy Class
Chinese GB/T 11883‐2002 Class III
Equivalent to OIML R76
Tare Range
100% F.S.
Zero Range
4% F.S.
Stable Time
≤10sec
Overload
100% F.S. + 9e
Safety Load
125% F.S.
Ultimate Load
400% F.S.
Battery Life
80 hours ~ 200 hours with 6V/10Ah battery
60 hours ~ 100 hours with 6V/5Ah battery
Scale Battery
6V/10Ah or 6V/5Ah rechargeable battery
Op. Temp.
‐10 ~ +40
Op. Humidity
20 ≤90%
Display
1.5 inch (38.1mm) ultra‐luminance LED
1.2 inch (30mm) ultra‐luminance LED
4. Quick Start
This Quick Start will guide the user through these basic operations on the
crane scale. To make full use of
this versatile scale, refer to Advanced
Operation section of this guide.
POWER ON
Action
o To P
OWER
O
N
the scale, press ON/OFF button on the scale for 1
second.
Function
o Scale will go through poweron test, battery check and initialization.
Condition
o
Poweron test is progressing when display flashes the following
characters twice. If scale
doesnt pass the test, error message will
display.