- 22 -
RSK24-2000/2500
CONTROL UNIT
English
0 - AUTOMATIC MODE pulse/signal
START STOP closing safety opening safety edge opening photocell obstacle detection
automation state
closed open lock
1
-- - -
opened - lock
3
lock
4
- lock
4
-
closing reopen
2
lock
2
reopen
2
- lock
7
reopen
1
opening - lock
2
- reverse and lock lock
7
reverse and lock
locked by STOP while closing
close - - - - -
locked by STOP while opening
close - - - - -
1 - 4-STEP pulse/signal
START STOP closing safety opening safety edge opening photocell obstacle detection
automation state
closed open lock
1
-- - -
opened lock
5
lock
3
lock
4
- lock
4
-
closing reopen
2
lock
2
reopen
2
- lock
7
reopen
1
opening - lock
2
- reverse and lock lock
7
reverse and lock
locked by STOP while closing
close - - - - -
locked by STOP while opening
close - - - - -
2 - SUPER AUTOMATIC pulse/signal
START STOP closing safety opening safety edge opening photocell obstacle detection
automation state
closed open lock
1
-- - -
opened close
1
lock
3
lock
4
- lock
4
-
closing reopen lock
2
reopen
2
- lock
7
reopen
1
opening reclose lock
2
- reverse and lock lock
7
reverse and lock
locked by STOP while closing
close - - - - -
locked by STOP while opening
close - - - - -
3 -
SEMIAUTOMATIC with STOP
pulse/signal
START STOP closing safety opening safety edge opening photocell obstacle detection
automation state
closed open lock
1
-- - -
opened close lock
1
lock
6
- lock
6
-
closing reopen lock
2
reopen
2
- lock
7
reopen
1
opening lock
2
lock
2
- reverse and lock lock
7
reverse and lock
locked by STOP while closing
close - - - - -
locked by STOP while opening
close - - - - -
4 - STEP-BY-STEP pulse/signal
START STOP closing safety opening safety edge opening photocell obstacle detection
automation state
closed open lock
1
-- - -
opened close lock
1
lock
6
- lock
6
-
closing lock
8
lock
2
reopen
2
- lock
7
reopen
1
opening lock
2
lock
2
- reverse and lock lock
7
reverse and lock
locked by STOP while closing
close - - - - -
locked by STOP while opening
close - - - - -
Legend:
lock
1
: locks and inhibits signals until a START command
lock
2
: locks until a START command to close
lock
3
: locks until a START command to close ignoring pause time
lock
4
: locks as long as the photocell is covered, ignoring pause time
lock
5
: if the START command is given within the f rst 3 seconds of the opening pause, will lock until a new START command is given to close
lock
6
: in spite of a START, the gate is locked as long as the photocell is covered, then it will close
lock
7
: locks as long at the photocell is covered; when the photocell is uncovered will complete the movement
lock
8
: locks until a START command to reopen
close
1
: closes ignoring the pause time - NOTE: If this occurs after an obstacle is detected during closing, will LOCK until
a new START is given to reclose slowly
reopen
1
: reopens slowly
reopen
2
: reopens -
NOTE
: If this occurs after an obstacle is detected during opening, will LOCK until a new START is given to reclose slowly
reverse and lock: reverses the movement for 2 seconds and locks - a START is necessary to reclose slowly