PAGE 36
CONFIGURING COMPRESSOR MODULE
To congure the Compressor module, press and hold anywhere on the module, this
will show the compressor settings page. Tap the option you wish to set.
Tap again to unset it.
1. Press and hold anywhere on the
Compressor module.
Disable When Engine OFF ensures that the compressor
will only run when the engine is on, this prevents any
damage to the compressor motor or blown fuses if the
battery levels are too low to operate it.
CONFIGURING PRESSURE CONTROL
2. Then set the Maximum System Pressure
1. Tap Pressure Control Installed
To activate the optional Pressure Control feature, tap the Pressure Control Installed
button then set the Maximum System Pressure to set the upper limit that can be
used when inating your items.
This must be less than the minimum limit of your compressor’s pressure switch
(e.g. For an ARB CO35 100psi pressure switch set it to 65psi, for an ARB 180901
150psi pressure switch set it to 130 psi).
2. Compressor settings page (Disable
When Engine OFF is set by default)