Training manual ALTEAS & GENUS ONE
Page. 51 of 88
6.7.1 CO2 adjustment Intermediate power
1
Switch on the boiler at the maximum power (using
“FLUE CLEANER” function DHW max power)
2
Wait till the value of the CO2 on the exhaust
analyser is stable.
3
Compare the CO2 value with the values in the table
below.
4
If the CO2 value is not ok press “OK” button and the
display shows the adjustment bar.
5
Using the buttons “<” and “>” to adjust the CO2
value (it is possible modify the CO2 of a value
±0,5%).
Note: To see the CO2 variation it needs to finish
this procedure and perform 5 ignitions of the
boiler.
6
To save the new setting push the button “Ok
CO2
Type of gas
12KW
18 KW
24 KW
30 KW
35KW
G20 20 mb
8,6% ± 0,7
8,6% ± 0,7
8,6% ± 0,7
8,6% ± 0,7
8,6% ± 0,7
G30 29 mb
G31 37 mb
10,0% ± 0,7
10,0% ± 0,7
10,0% ± 0,7
10,0% ± 0,7
10,0% ± 0,7
G231
N.B.: Values with casing closed.