6.3 EXHAUST SYSTEMS
The boiler is set up for connection to a 60/100 coaxial air intake and flue gas exhaust ducting system. To use
split types of suction and exhaust, one of the two air intakes must be used.
Remove the top of the air intake by cutting it with a suitable knife.
Type
Ø
(mm)
Material
18 KW
(m)
24 KW
(m)
30 KW
(m)
35 KW
(m)
Coaxial
system
C13 C33 C43
60/100
Al/PP
14
12
10
8
B 33
60/100
Al/PP
14
12
10
8
C13 C33 C43
80/125
Al/PP
42
36
30
24
B 33
80/125
Al/PP
42
36
30
24
Twin flue
C13
80/80
PP
36 (x=y)
36 (x=y)
30 (x=y)
24 (x=y)
C33
80/80
PP
60 (x=y)
60 (x=y)
50 (x=y)
40 (x=y)
C43
80/80
PP
36 (x=y)
36 (x=y)
30 (x=y)
24 (x=y)
C53 C83
80/80
PP
50 (x+y)
60 (x+y)
60 (x+y)
45 (x+y)
B23
80/80
PP
20 (y)
60 (y)
50 (y)
45 (y)
C13
60/60
PP
6 (x=y)
5 (x=y)
2 (x=y)
/
C33
60/60
PP
7 (x=y)
6 (x=y)
2,5 (x=y)
/
C43
60/60
PP
6 (x=y)
5 (x=y)
2 (x=y)
/
C53 C83
60/60
PP
5 (x+y)
11 (x+y)
60 (x+y)
6 (x+y)