Training manual ALTEAS & GENUS ONE
Page. 80 of 88 Version 2V2.
9.3.4 Menù 5 : Zone 2 parameters
4
3
5
Zone 1 pump status
OFF: switch-off
ON: switch-on
(only visualization)
/
4
4
ZONE 1 ZONE MODULE SETTINGS (visible only with zone module connected)
4
4
0
Zone 1 pump modulation
0: Fix
1: Modulating (ΔT)
2: Modulating (pressure)
1
4
4
1
ΔT for pump modulationa
4 ÷ 25
7 (par. 420=0)
20 (par. 420=1)
4
4
2
Pump fixed speed setting (with
par. 440 = 0)
20 ÷ 100
100
Menù
Sub Menù
Parameter
Function
Range
Default
setting
5
0
SETPOINT
5
0
2
Temperature setpoint zone 2
Par 525 ÷ Par 526
/
5
2
ZONE 2 SETTING
5
2
0
Select high or low temperature
for zone 2
0: low temperature
1: high temperature
1
5
2
1
Thermoregulation mode
selection
0: fixed delivery temperature
1: basic thermoregulation
2: only room probe
3: only outside probe
4: room probe + external probe
1
5
2
2
Select thermoregulation curve
0_2 ÷ 1_0 (par. 520=0)
1_0 ÷ 3_5 (par. 520=1)
(with Auto function enabled)
0_6 (par 520=0)
1_5 (par 520=1)
5
2
3
Select thermoregulation curve
parallel shifting
-7 ÷ 7 (par. 520=0)
-14 ÷ 14 (par. 520=1)
(with Auto function enabled )
0
5
2
4
Influence of the room probe on
thermoregulation
0 ÷ 20
(with Auto function enabled )
20
5
2
5
Zone 2 maximum heating
temperature (°C)
20 ÷ 45 (par. 520=0)
35 ÷ 82 (par. 520=1)
45 (par. 520=0)
82 (par. 520=1)
5
2
6
Zone 2 minimum heating
temperature (°C)
20 ÷ 45 (par. 520=0)
35 ÷ 82 (par. 520=1)
20 (par. 520=0)
35 (par. 520=1)
5
3
DIAGNOSTICS
5
3
2
Zone 2 delivery temperature
(°C)
(only visualization)
/
5
3
3
Zone 2 return temperature (°C)
(only visualization)
/
5
3
4
Heating request by zone 2
OFF: no
ON: yes
(only visualization)
/
5
3
5
Zone 2 pump status
OFF: switch-off
ON: switch-on
(only visualization)
/
5
4
ZONE 2 ZONE MODULE SETTINGS (visible only with zone module connected)
5
4
0
Zone 2 pump modulation
0: Fix
1: Modulating (ΔT)
2: Modulating (pressure)
1
5
4
1
ΔT for pump modulationa
4 ÷ 25
7 (par. 520=0)
20 (par. 520=1)

Table of Contents