Training manual ALTEAS & GENUS ONE
Page. 78 of 88 Version 2V2.
Maximum DHW power
(do not modify this parameter,
modify only in even of PCB
replacement)
Minimum boiler power
(do not modify this parameter,
modify only in even of PCB
replacement)
Maximum absolute heating
power
(do not modify this parameter,
modify only in even of PCB
replacement)
Select of heating delay manage
0: manual (set with par. 2 36)
1: automatic
Heating delay (min), enabled by
par. 2 35= 0
Heating post-circulation (min)
Pump modulation on heating
ΔT for pump modulation (°C)
Heating circuit pressure
required to request filling (error
message) (0,x bar)
0 ÷ 60
(with Auto function working)
Heating water pressure
detection device
0: temperature probes only
1: pressure switch
2: pressure sensor
External temperature correction
(°C)
Sanitary comfort function
0: disabled
1: enabled for 30 minutes after a heating request
2: always enabled
Sanitary delay start
(anti water hammering) (dec)
Sanitary switch off logic
0: anti-scale (62 o 65°C).
1: set-point+4°C
Sanitary post-circulation and
post-ventilation
0: Post-ventilation: Tflow<75°C = no post-
ventilation; Tflow>75°C = 3 min (minimum
speed); Post-circulation: 30sec
1: Post-ventilation: 3min
Post-circulation: 3min
Heating start delay after sanitary
(min)
Antilegionella function (only for
boilers with external tank and
NTC sensor – par. 228 = 1)
Antilegionella time
(only for boilers with external
tank and NTC sensor – par. 228
= 1). The setting temperature is
always 60°C (tank temperature).