Water missing on the primary circuit (P<Pmin) for boiler with pressure
sensor(par. 247=2)
Heating return probe open circuit or no signal (NTC2)
Outdoor probe open circuit or no signal
Circulation or presence of water: Gradient Tman > 7°C/sec
Circulation or presence of water: Tman – Trit> 55°C
Circulation or presence of water: Trit > Tman + 10°C
Low primary circuit pressure(P<P
SIGNALLING
): fill up
Tank low probe open circuit or no signal (solar)
Tank probe open circuit or no signal
Solar collector probe open circuit or no signal
Sanitary inlet probe open circuit (solar)
Solar manifold temperature low
GP – GIU communication error
More than 5 resets executed in 15 minutes
Low voltage fault (error< 150Vac; exit condition>170Vac)
Sched. Maintenance-Call Service
COMMUNICATION WITH PERIPHERALS
Room probe open or short circuit
Flame missing (after 5 times 5P6)
Flame detected with gas valve closed
Flame detected with gas valve closed (after 20sec of error 502)
In lockout after 6 flame lifts 5P3
Flame detachment during operation
Thermal fuse contact open (only China)
Fan warning (too much pressure loses on air/flue duct): fan 6000Rpm for
20min and if the problem remain error 612. Exit condition: the problem is
solved within 20min.
Fan turns too slow or wire not connected or 20min error 611
Heating delivery probe zone 1 open or short circuit
Heating delivery probe zone 2 open or short circuit
Heating delivery probe zone 3 open or short circuit
Heating return probe zone 1 open or short circuit
Heating return probe zone 2 open or short circuit
Heating return probe zone 3 open or short circuit
Hydraulic scheme not defined
COMBUSTION CONTROL SYSTEM (CCS)
The boiler must be calibrated
Mismatch kW Size, ID combustion (Set parameter 229)
Decupling clip-in required