5200 Series Programming Instructions
9
80-9352-0022-020 Rev 2 06/23
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Speed/Force & Timing/Location Settings
Select the Speed/Force Settings tab (Figure 23)
and Timing/Location Settings tab (Figure 24) to
adjust the operator to meet BHMA requirements.
Select each option and choose the setting or
adjust slider to the desired value.
Speed/Force and Timing/Location
settings must be adjusted to meet
ANSI BHMA A159.19 (American National
Standard for Power Assist and Low
Energy Power Operated Doors)
requirements for opening and closing
based on door weight and width.
Figure 23 Figure 24
Figure 25
D. Adjust the Operator Settings. (cont.)
Backcheck
Location
90°
75°
Latch
Location
Sweep Speed
0°
5°
5°
Options Settings
Select setting and change value then save.
(Figure 25)
Option definitions:
y Latch Assist:
At closed position, after an activation, the door
is pulled in.
After the door has closed, the door is pulled in
to assist with latch release/engagement.
y Obstruction Detect While Closing:
Door will reverse to open position if it hits an
obstruction while closing.
y Power Close:
Additional force is applied to assist the door
closing between 7° and 2°.
y Ignore Obstruction <10° From Closed:
Used with a door mounted presence sensor.
The operator will ignore the obstruction input
from the sensor in the last 10 degrees of
closing.