Instructions for Installation of
Keypad Rim & Mortise Exit Devices
KP8877 / KP8878
KP8977 / KP8978
To Set Unlock Time:
• Master Code* (Yellow LED Begins to Blink
Slowly)
• 85# Time Duration# (01-99 Sec) 0# (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)
All of the following procedures start with 99# (continued).
If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.
To Delete a User Number:
• Master Code* (Yellow LED Begins to Blink Slowly)
• User Number# (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 56# 0# = Enable, 1# = Disable User Number# (04-99) (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)
To Disable / Enable a User Number:
Optional Equipment
• Data Transfer Device (DTD) - used to download the user and transaction type.
• Remote Unlocking - 52-2071 (has a 2-pin connector with 2 wires). When
wired to a remote normally open momentary switch, a momentary switch
closure is used used for remote unlocking of keypad exit device.
Remote unlocking
connector placement
Inside Escutcheon
Programming Instructions