Loading...
Lower
lug
Fire
stop
plate
Wires & connector
go through fire stop
plate
Lower
lug
Outside
of door
Connector &
wires through
fire stop plate
Flat
washer
#8-32 x 1-1/4’
Pan head screw
Inside of
door
Outside
of door
• From the outside of the door through
the Fire Stop Plate (if required)
• For non 12- exit devices feed wire
harness from keypad assembly through
hole in door
Inside
of door
• From the inside of the door, use
the #8-32 x 1-1/4” pan head
screw with the flat washer to
attach the escutcheon using the
lower lug
• Straighten keypad escutcheon
and tighten the #8-32 x 1-1/4”
pan head screw
13
C
L
Mortise Installation Instructions for
KP8900 Series (Continued)
6. Insert Wires and Connector
8
Copyright © 2014. 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
02/28/21
18 A7137D • 800-810-WIRE (9473) • www.sargentlock.com
Installation Instructions
Mortise Exit Device
KP8977 / KP8978