29
5.2 I Technical data
Performances : air at 26 °C / water at 26 °C / humidity at 80 %
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
Operang power (max-min speed) kW
5.5 - 1,5 7 - 2 9.5 - 2.3 13 - 2.4 15 - 2.5 20 - 2.8
Consumed power (max-min speed) kW
0,9 - 0,1 1.1 - 0.15 1.4 - 0.2 2 - 0.1 2.5 - 0.15 3.3 - 0.2
COP (max-min speed)
6.1 - 14.4 6.5 - 13.4 6.7 - 13.5 6.5 - 16.4 6 - 16.3 6.2 - 16.5
Performances : air at 15 °C / water at 26 °C / humidity at 80 %
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
Operang power (max-min speed) kW
3,9 - 1,1 5.5 - 1.4 7 - 1.5 9 - 1.7 11 - 1.9 15 - 2.2
Consumed power (max-min speed) kW
0,8 - 0,1 1.1 - 0.2 1.3 - 0.2 1.9 - 0.2 2.3 - 0.25 3 - 0.3
COP (max-min speed)
5.2 - 8 5.2 - 6.4 5.3 - 6.6 4.8 - 7.8 4.8 - 7.7 5 - 7.3
Technical specicaons
Operang temperature
Air from -7 to 43 °C
Water
In “heang mode” from: 15 à 40 °C
In “cooling mode” from: 8 à 28°C
Operang pressure
Refrigerant from 0,5 to 42 bar (from 0,05 to 4,2 MPa)
Water from 0 to 2 bar (from 0 to 0,2 MPa)
Power supply 220 - 240 V / 1 phase / 50-60 Hz
Admissible variaon in voltage ± 6 % (during operaon)
Hydraulic connecons 2 PVC, 1/2 unions Ø 50
Type of refrigerant uid R32
Protecon rang IPX4
Frequency bands GHz 2,400 - 2,497
Radiofrequency emission power dBm +19,5
Installaon locaon outdoors
Technical specicaons
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
EN 17645 rang
A A A A A A
EN 17645 SCOP
7.5 7.5 8 9.6 7.7 8.5
Nominal operang power A
4.9 6.3 8 10.2 13.6
Max operang power A
8 9 13 16 19
Minimum cable secon* mm²
3 x 2,5 3 x 4
Acousc power** (max-min) dB(A)
59-47 64-51 67-55 70-57
Acousc pressure at 10m** (max-min) dB(A)
28-16 33-20 36-24 39-26
Recommended water ow /h
3 4 5 6 7
Refrigerant uid load
kg
0.3 0.45 0.6 0.7 1.0
Tonn CO2
eq.
0.20 0.30 0.41 0.47 0.68
Approximate weight kg
38.5 41.5 46 52.5 66
The technical specicaons are provided for informaon purposes only. The manufacturer reserve the right to make changes without prior noce.
* Values provided for informaon purposes for a maximum length of 20 metres (calculaon base: NFC15-100), must be checked and adapted to the
installaon condions and standards of the installaon country.
** Acousc values at 10 m in accordance with Direcves EN60704-1:2010+A11:2012 standard
EN