29
5.2 I Technical data
Performances : air at 26 °C / water at 26 °C / humidity at 80 %
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
Operang power (max-min speed) kW
5.5 - 1,5 7 - 2 9.5 - 2.3 13 - 2.4 15 - 2.5 20 - 2.8
Consumed power (max-min speed) kW
0,9 - 0,1 1.1 - 0.15 1.4 - 0.2 2 - 0.1 2.5 - 0.15 3.3 - 0.2
COP (max-min speed)
6.1 - 14.4 6.5 - 13.4 6.7 - 13.5 6.5 - 16.4 6 - 16.3 6.2 - 16.5
Performances : air at 15 °C / water at 26 °C / humidity at 80 %
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
Operang power (max-min speed) kW
3,9 - 1,1 5.5 - 1.4 7 - 1.5 9 - 1.7 11 - 1.9 15 - 2.2
Consumed power (max-min speed) kW
0,8 - 0,1 1.1 - 0.2 1.3 - 0.2 1.9 - 0.2 2.3 - 0.25 3 - 0.3
COP (max-min speed)
5.2 - 8 5.2 - 6.4 5.3 - 6.6 4.8 - 7.8 4.8 - 7.7 5 - 7.3
Technical specicaons
Operang temperature
Air from -7 to 43 °C
Water
In “heang mode” from: 15 à 40 °C
In “cooling mode” from: 8 à 28°C
Operang pressure
Refrigerant from 0,5 to 42 bar (from 0,05 to 4,2 MPa)
Water from 0 to 2 bar (from 0 to 0,2 MPa)
Power supply 220 - 240 V / 1 phase / 50-60 Hz
Admissible variaon in voltage ± 6 % (during operaon)
Hydraulic connecons 2 PVC, 1/2 unions Ø 50
Type of refrigerant uid R32
Protecon rang IPX4
Frequency bands GHz 2,400 - 2,497
Radiofrequency emission power dBm +19,5
Installaon locaon outdoors
Technical specicaons
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
EN 17645 rang
A A A A A A
EN 17645 SCOP
7.5 7.5 8 9.6 7.7 8.5
Nominal operang power A
4.9 6.3 8 10.2 13.6
Max operang power A
8 9 13 16 19
Minimum cable secon* mm²
3 x 2,5 3 x 4
Acousc power** (max-min) dB(A)
59-47 64-51 67-55 70-57
Acousc pressure at 10m** (max-min) dB(A)
28-16 33-20 36-24 39-26
Recommended water ow m³/h
3 4 5 6 7
Refrigerant uid load
kg
0.3 0.45 0.6 0.7 1.0
Tonn CO2
eq.
0.20 0.30 0.41 0.47 0.68
Approximate weight kg
38.5 41.5 46 52.5 66
The technical specicaons are provided for informaon purposes only. The manufacturer reserve the right to make changes without prior noce.
* Values provided for informaon purposes for a maximum length of 20 metres (calculaon base: NFC15-100), must be checked and adapted to the
installaon condions and standards of the installaon country.
** Acousc values at 10 m in accordance with Direcves EN60704-1:2010+A11:2012 standard