15
2.3.3 Anfreeze protecon (if heang priority is acvated)
• For the anfreeze protecon to work, the heat pump must be powered and the ltraon pump
acvated. If the heang priority is acvated, the anfreeze protecon will work automacally.
When the heat pump is on stand-by, the system monitors the ambient temperature and the water temperature in
order to acvate the anfreeze programme if required. The anfreeze protecon is automacally acvated when the
air temperature or water temperature are less than 2°C and when the heat pump has been shut down for more than
120 minutes. When the anfreeze protecon is running, the appliance acvates its compressor and the ltraon pump
to reheat the water unl it exceeds 2°C .The heat pump automacally leaves the anfreeze mode when the ambient
temperature is higher than or equal to 2°C or when the heat pump is acvated by the user.
2.4 I User funcons
2.4.1 Locking/unlocking the keypad
• Press for 5 seconds to unlock the keypad. The keypad is automacally locked aer 60 seconds of inacvity.
2.4.2 Seng the me (clock)
• Unlock the keypad: the main menu is displayed.
• Press 5 seconds to enter the clock seng interface.
• Press - the hours are blinking. Press and to adjust the hours.
• Press - the minutes are blinking. Press and to adjust the minutes.
• Press to conrm and return to the main screen.
2.4.3 Seng the mer
• If two dierent mers are set up on the ltraon pump and on the heat pump, the mer on the
ltraon pump will be ignored.
• If a mer is set on the heat pump, it is recommended to acvate the “heang priority” to
ensure that the pool will be heated during this me slot (the heat pump only works when the
ltraon pump is also working).
Three mer programs can be set up on the heat pump.
• Unlock the keypad: the main menu is displayed.
• Press to enter Timer 1 funcons. Timer 1 is blinking.
• Press to enter Timer 1 ON hours. Press and to adjust the start hours.
• Press again to set the minutes. Press and to adjust the start minutes.
• Press again to set Timer 1 OFF hours and minutes as done in the previous steps.
• Press to conrm Timer 1 ON/OFF sengs.
• Press and to set Timer 2 ON/OFF sengs.
EN