EasyManuals Logo

Atlas Copco PNS 1250 Cud S3A/T3 APP User Manual

Atlas Copco PNS 1250 Cud S3A/T3 APP
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
- 75 -
LP intercooler pressure below
normal
Choked air filter elements. Remove and inspect air filter elements.
Clean or replace elements, if necessary.
Intercooler relief valve(s) leaking. Remove valve(s), clean and inspect.
Electric blow-off valve malfunctioning. Check interstage pressure. Check functioning of loading
solenoid valve. Replace diaphragm of blow-off valve if
necessary.
Air leak between LP and
HP compressor element. Inspect pipe connections and intercooler.
Replace leaking O-rings, gaskets or intercooler, if necessary.
LP compressor element not in order. Have LP compressor element inspected by Atlas Copco.
Intercooler clogged internally. Consult Atlas Copco.
LP intercooler pressure above
normal
Aftercooler clogged internally. Consult Atlas Copco.
HP compressor element not in order. Have HP compressor element inspected by Atlas Copco.
HP silencer and/or check valve give restriction. Check and take corrective action.
MP intercooler pressure below or
above normal
MP or HP element is failing. Consult Atlas Copco.
MP safety valve is leaking. Remove valve, clean and inspects parts.
Symptom Possible cause Corrective action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PNS 1250 Cud S3A/T3 APP and is the answer not in the manual?

Atlas Copco PNS 1250 Cud S3A/T3 APP Specifications

General IconGeneral
BrandAtlas Copco
ModelPNS 1250 Cud S3A/T3 APP
CategoryAir Compressor
LanguageEnglish

Related product manuals