Page #46 background imageLoading...
Page #46 background image
- 47 -
5.2.9.4 Set Language
1. Press the SETTINGS VIEW button.
2. Scroll to ‘1000 GENERAL SETTINGS’.
3. Press ENTER.
4. Scroll to ‘1300 LANGUAGES’.
5. ENTER the LANGUAGES menu.
6. ENTER the ‘SETTINGS’ parameter.
7. Scroll to the preferred language.
8. Press ENTER.
9. Now press BACK until you are back in the Main
View (or in the menu you require).
5.2.9.5 Set Units
1. Press the SETTINGS VIEW button.
2. Scroll to ‘1000 GENERAL SETTINGS’.
3. Press ENTER.
4. Scroll to the unit you would like to change:
‘1340 TEMPERATURE UNITS’
‘1350 PRESSURE UNITS’
‘1360 FUEL FLOW UNITS’
‘1370 AIR FLOW UNITS’
5. ENTER the preferred menu.
6. ENTER the ‘SETTINGS’ parameter.
7. Scroll to the preferred setting.
8. Press ENTER.
9. Now press BACK until you are back in the Main
View (or in the menu you require).
5.2.9.6 Change Display Settings
1. Press the SETTINGS VIEW button.
2. Scroll to ‘1000 GENERAL SETTINGS’.
3. Press ENTER.
4. Scroll to ‘1310 DISPLAY BACKLIGHT’.
5. ENTER the DISPLAY BACKLIGHT menu.
6. Scroll to the setting you would like to change.
7. Press ENTER.
To change a setting, the red figure is editable.
Scroll up/down and press ENTER to change. Use
left/right to shift between editable figure.
8. Now press BACK until you are back in the Main
View (or in the menu you require).
5.2.9.7 Go To Diagnostics
1. Press the SETTINGS VIEW button.
2. Scroll to ‘1000 GENERAL SETTINGS’.
3. Press ENTER.
4. Scroll to ‘1150 DIAGNOSTICS’.
5. ENTER the Diagnostics menu.
6. ENTER the ‘ENABLE’ parameter.
7. Scroll to ‘ON’ and press ENTER.
Now the ECU gets PAC (ignition) and you can
perform ECU diagnostics (read DM1 List, DM2
List, ECU values, perform engine diagnostics,
…).
8. Now press BACK until you are back in the Main
View (or in the menu you require).
9. To leave Diagnostics, press the STOP button.
5.2.9.8 Set the AutoLoad Function
1. Press the SETTINGS VIEW button.
2. Scroll to ‘1000 GENERAL SETTINGS’.
3. Press ENTER.
4. Scroll to ‘1160 AUTO LOAD’.
5. ENTER the ‘FUNCTION’ menu.
6. Scroll to AUTO LOAD setting.
7. Press ENTER.
Now the AutoLoad function is active, and as soon
as the unit is Ready To Start, the display will show
the Auto Load icon.
8. Now press BACK until you are back in the Main
View (or in the menu you require).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PNS 1250 Cud S3A/T3 APP and is the answer not in the manual?

Atlas Copco PNS 1250 Cud S3A/T3 APP Specifications

General IconGeneral
BrandAtlas Copco
ModelPNS 1250 Cud S3A/T3 APP
CategoryAir Compressor
LanguageEnglish

Related product manuals