- 60 -
Reassemble in reverse order of dismantling.
Inspect and tighten all air intake connections.
Reset the air filter vacuum indicator by pushing
the reset button (8).
6.4.2.4 Cleaning the filter element
Withdraw the filter element (see section 6.4.2.3).
Reinstall the dust trap cover to protect the air
intake system while cleaning the element.
Carefully knock the end faces of the filter element
on a flat surface to remove the dry contaminant.
Never strike on a hard surface. Then blow dry air
up and down the pleats in the reverse direction of
normal flow; subsequently blow up and down the
pleats on both sides of the element. The air
pressure may not exceed 5 bar (73 psi) and a
reasonable distance must be maintained between
the hose nozzle and the pleats.
If the contaminant is oily, soak the element for 10
minutes in luke-warm water in which a non-
foaming detergent is dissolved. Then, move the
element to and fro in the solution for 5 minutes.
Rinse with soft water until the drain water is clear.
Let the element dry. Never use compressed air to
hasten drying.
Inspect the element by placing a light inside it.
Spots or ruptures of the paper render the element
unfit for further use.
Reassemble in reverse order of dismantling.
Reset the air filter service indicator by pushing the
reset button (8).
7 Air filter contamination indicator
8 Reset button
9 Yellow indicator
Never run the compressor without
air filter element.
8
7
9
!