Instruction Manual
108 2954 2510 03
10 Legislation
10.1 Parts, subjected to Pressure Equipment Directive
97/23/EC, cat. II and above
Safety valve: cat. IV
10.2 Parts, subjected to Simple Pressure Vessel Directive
87/404/EC
Air Oil separator
10.3 Parts, subjected to cat. I and covered by the Machine
Directive 89/392/EC
All other parts
10.4 Parts, subjected to art. I, paragraph 3.3
All other parts
XRHS 506 -
XRHS 1100 CD6
XRVS 476 -
XRVS 1000 CD6
Set pressure bar(e) 25 30
psi 363 435
Design temperature °C 130 130
°F 266 266
XRHS 506 -
XRHS 1100 CD6
XRVS 476 -
XRVS 1000 CD6
Standard Cold start equipment
Design pressure bar(e) 30 30
psi 435 435
Design temperature max. °C 130 130
°F 266 266
Design temperature min. °C -10 -25
°F 14 -13
Volume l 143 143
US gal 37.7 37.7
Imp gal 31.5 31.5
cu.ft 5 5