4.11.3 Replacing the coolant
Drain
Completely drain the entire cooling system.
Used coolant must be disposed or recycled in accordance with laws and local regulations.
Flush
Flush twice with clean water. Used coolant must be disposed or recycled in accordance with
laws and local regulations.
From the Atlas Copco Instruction book, determine the amount of PARCOOL EG required and
pour into the radiator top tank.
It should be clearly understood that the risk for contamination is reduced in case of proper
cleaning.
In case a certain content of ‘other’ coolant remains in the system, the coolant with the lowest
properties influences the quality of the ‘mixed’ coolant.
Fill
To assure proper operation and the release of trapped air, run the engine until normal engine
operation temperature is reached. Turn off the engine and allow to cool.
Recheck coolant level and add if necessary.
Caution: do not top off when the engine is hot.