SNMP ENTERPRISE ATTRIBUTES
8-6 TranScend Chassis – Operation Manual
innoTransTranscendModuleSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The serial number for the module.”
::= { innoTransTranscendModuleEntry 5 }
innoTransTranscendModuleTemp OBJECT-TYPE
SYNTAX HeTenthCentigrade
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The module temperature.”
::= { innoTransTranscendModuleEntry 6 }
innoTransTranscendModuleHwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The hardware version(s) of the module.”
::= { innoTransTranscendModuleEntry 7 }
innoTransTranscendModuleDisplayName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The slot module display name in more user friendly format.
For module spans multiple slots, this attribute shows the same display name
on all occupied slots.”
::= { innoTransTranscendModuleEntry 8 }
--
-- Module Laser Table: contains optics attributes.
--
innoTransTranscendModuleLaserTable OBJECT-TYPE
SYNTAX SEQUENCE OF InnoTransTranscendModuleLaserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
“This table contains a set of data for laser elements in the module.”
::= { innoTransTranscendEquip 2 }
innoTransTranscendModuleLaserEntry OBJECT-TYPE
SYNTAX InnoTransTranscendModuleLaserEntry
MAX-ACCESS not-accessible
STATUS current
CHAPTER 8: