AudioCodes Mediant E-SBC 2. Installing the Hardware
BroadCloud SIP Trunk 13 AudioCodes Mediant E-SBC
To connect the device to the IP-PBX (LAN):
1. If the device's IP isn't configured yet, connect as shown in Section 3.
2. If the device's IP has already been configured:
a. Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45
port labeled S1 / LAN GE port 3.
b. Connect the other end to your local network LAN layer 2 switch port. This port will
be used to communicate with the local IP-PBX.
2.2.1.3 Connecting to the Power Supply
The device receives power from a standard alternating current (AC) electrical outlet. The
connection is made using the supplied AC power cord.
Table 2-7: Power Specifications
Physical Specification Value
Input Voltage Single universal AC power supply 100 to 240V
AC Input Frequency 50 to 60 Hz
AC Input Current 0.8A
Warnings: The device must be connected to a socket-outlet providing a protective
earthing connection. Use only the AC power cord that is supplied with the device.
To connect the device to the power supply:
1. Connect the line socket of the AC power cord (supplied) to the device's AC power
socket (labeled 100-240V~50-60 Hz 0.8A), located on the rear panel.
Figure 2-11: Connecting to the Power Supply
2. Connect the plug at the other end of the AC power cord to a standard electrical outlet.
3. Press the power switch to on (I) position so that the device receives power; the
POWER LED on the front panel is lit green.