Protective earthing screw.
2 100-240V~1.5A
50-60Hz
3-Prong AC power supply entry.
2.3.4 Cabling
2.3.4.1 Grounding the Device
The device must be connected to earth (grounded) using an equipment-earthing conductor.
Protective Earthing
The equipment is classified as Class I EN60950 and UL60950 and must be
earthed at all times.
For Finland: Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan.
For Norway: Apparatet rna tilkoples jordet stikkontakt.
For Sweden: Apparaten skall anslutas till jordat uttag.
To ground the device:
1. Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
grounding screw (located on the rear panel), using the supplied washer.
Figure 2-14: Grounding the Device
2. Connect the other end to a protective earthing (according local regulations).