AudioCodes Mediant E-SBC 2. Installing the Hardware
BroadCloud SIP Trunk 15 AudioCodes Mediant E-SBC
2.3.3 Rear Panel
Figure 2-13: Rear Panel
Table 2-10: Rear Panel
Item # Label Description
1
Protective earthing screw.
2 100-240V~1.5A
50-60Hz
3-Prong AC power supply entry.
2.3.4 Cabling
2.3.4.1 Grounding the Device
The device must be connected to earth (grounded) using an equipment-earthing conductor.
Protective Earthing
The equipment is classified as Class I EN60950 and UL60950 and must be
earthed at all times.
For Finland: Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan.
For Norway: Apparatet rna tilkoples jordet stikkontakt.
For Sweden: Apparaten skall anslutas till jordat uttag.
To ground the device:
1. Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
grounding screw (located on the rear panel), using the supplied washer.
Figure 2-14: Grounding the Device
2. Connect the other end to a protective earthing (according local regulations).
2.3.4.2 Connecting to Ethernet
Up to four 10/100/1000Base-T (Gigabit Ethernet) RJ-45 ports supporting half- and full-
duplex modes, auto-negotiation, and straight or crossover cable detection, allow
connecting to the LAN/WAN.