Hardware Installation Manual 18 Document #: LTRT-10236
Mediant 800 MSBR
Item # Label Description
7 FE (Optional) Eight Fast Ethernet (10/100Base-TX) RJ-45 LAN
ports for connecting IP phones, computers, or switches.
These ports support half- and full-duplex modes, auto-
negotiation, and straight or crossover cable detection.
8 // Reset pinhole button for resetting the device and optionally,
for restoring the device to factory defaults.
To restore the device to factory defaults, do the following:
With a paper clip or any other similar pointed object, press
and hold down the pinhole button for at least 12 seconds,
but no longer than 25 seconds.
9 CONSOLE RS-232 serial communication port (RJ-45).
10 USB/WWAN Two USB ports that can be used for various functionalities
such as 3G/4G cellular WAN modem or storage capabilities.