Hardware Installation Manual 5. Cabling the Device
Care in Handling Fiber Optic Cabling:
1. Excessive bending of the Fiber Optic Cable can cause distortion and signal losses.
2. Ensure the minimum bending radius recommended by the Fiber Optic Cable supplier.
3. Incoming optic cabling from the network infrastructure can originate from the top of
the rack or from another shelf within the rack. Preserve the minimum-bending ratio
indicated by the cable manufacturer.
4. To ensure full high-availability capabilities, the configuration of the interface to the IP
backbone must include certain redundant features from which two separate fiber optic
cables are entering the device.
Note:
The SFP modules and fiber-optic cables are not supplied. It is recommended that you
purchase the SFP modules from AudioCodes. For a list of orderable SFP modules,
see Appendix A on page 69, or contact your AudioCodes sales representative.
This AudioCodes device has been evaluated with the laser transceiver modules
(SFP) listed in Appendix A on page 69. If other SFP modules are used, the person
installing the device is solely responsible for the usage of correct SFP modules to
comply with local, applicable laser safety requirements and certification. AudioCodes
will not be held responsible for any damage to human body or equipment caused as a
result from the usage of SFP modules that are not listed in Appendix A on page 69.
Cable specifications:
WAN fiber-optic interface:
LC-type plug
WAN copper interface: see Section 5.2.1 on page 35
To connect the fiber-optic WAN GbE port:
1. Remove the protective dust plug from the SFP transceiver module.
Figure 5-4: Removing Protective Dust Plug Mediant 800B MSBR
Figure 5-5: Removing Protective Dust Plug Mediant 800C MSBR